  3. First-floor flat: a leak on old pipework nobody knew was live

Found and repaired by ADIFirst-floor flat, two bedrooms · ADI published case

A first-floor flat, a meter that never stopped, and old hot pipework left live after a boiler conversion

The meter showed a small leak with no water in use. When the flat was converted to a combination boiler, some old hot pipework had been left buried under the bathroom floor, still connected and under pressure.

Old copper hot water pipework and a grey waste hose in the void beneath a bath, where the leak was located
Original ADI photograph from this investigation: the old hot pipework under the bath where the leak was located.

What was happening

The external water meter showed a small but active leak with no water in use. The two-bedroom first-floor flat had a combination boiler, fitted when the property was converted from an open-vented hot water cylinder system. Not all of the old pipework had been taken out during that work.

What the engineer did

The hot feed was cut into and pressurised to 2 bar, and a gradual drop on the gauge confirmed a leak. Acoustic listening on the hallway and bathroom floors picked up water escaping through buried pipework. Tracer gas put in at 2.4 bar travelled through the pipes and surfaced at the leak point, which was traced to an area below the flat. A look under the bath showed how the old hot pipework was still connected.

What was found

The leak was on redundant hot water pipework from the old installation, buried under the bathroom floor. It was still joined to the hot tap feed through an isolation valve, so it had stayed under pressure.

What happened next

ADI capped off the old buried pipework and reconnected the hot tap feed directly to the newer pipework, taking the redundant section out of the live system altogether.

If you manage rentals

Renovation history matters. If a property has had a boiler conversion or a new bathroom, tell the office when you call: old pipework left in place is a common hiding place, and following it may mean getting into the flat below.

More residential jobs

House with a combination boiler · ADI published case

Damp hallway: a damaged hot pipe under the floor tiles

Water was pooling under the stairs and the boiler had been losing pressure for two weeks. Pressure testing, tracer gas and thermal imaging found a damaged 15 mm hot pipe under the hallway floor, plus a separate leaking WC valve.

Arrange a leak detection survey with ADI

Describe what the tenant has noticed, the type of property and the postcode. The office team will talk through the survey, give you a quote and current availability, and book the engineer.

0333 567 2621
  • Monday to Friday, 7:30am to 6:30pm
  • Calls reach ADI Leak Detection's office in High Wycombe. Engineers cover England, Scotland and Wales.